Mohammed Mezied, modified 3 Years ago.
Two Types of sediment
Keen Forecaster Posts: 4 Join Date: 10/9/21 Recent Posts
Hello, I'd want to simulate two different types of non-cohesive sediments (different sediment sizes) using different transport formulas. Is it possible to use a transport formula for each sediment type?
Victor Chavarrias, modified 3 Years ago.
RE: Two Types of sediment
Famous Fortune teller Posts: 97 Join Date: 4/24/20 Recent Posts
Yes, it is possible. E.g. of sed-file input:
1 | [Sediment] |
2 | Name = #Sediment1# Name of sediment fraction |
3 | SedTyp = bedload Must be "sand", "mud" or "bedload" |
4 | IniSedThick = 1.0000000e+000 [m] Initial sediment layer thickness at bed (overuled if IniComp is prescribed) |
5 | RhoSol = 2.6500000e+003 [kg/m3] Specific density |
6 | TraFrm = 1 Integer selecting the transport formula |
7 | CDryB = 1.5900000e+003 [kg/m3] Dry bed density |
8 | SedDia = 1.4142136e-03 [m] sediment diameter (D50) |
9 | ACal = 1 Calibration coefficient |
10 | RouKs = 0.000 |
11 | SusFac = 0.000 |
12 | [Sediment] |
13 | Name = #Sediment9# Name of sediment fraction |
14 | SedTyp = bedload Must be "sand", "mud" or "bedload" |
15 | IniSedThick = 1.0000000e+000 [m] Initial sediment layer thickness at bed (overuled if IniComp is prescribed) |
16 | RhoSol = 2.6500000e+003 [kg/m3] Specific density |
17 | TraFrm = 4 Integer selecting the transport formula |
18 | CDryB = 1.5900000e+003 [kg/m3] Dry bed density |
19 | SedDia = 2.3664319e-03 [m] sediment diameter (D50) |
20 | ACal = 8 Calibration coefficient |
21 | PowerB = 0.000000 Power b |
22 | PowerC = 1.500000 Power c |
23 | RipFac = 1.000000 Ripple factor or efficiency factor |
24 | ThetaC = 0.025000 Critical mobility factor |
Mohammed Mezied, modified 3 Years ago.
RE: Two Types of sediment
Keen Forecaster Posts: 4 Join Date: 10/9/21 Recent Posts
Thanks a lot for the reply